Sign In | Join Free | My himfr.com
Home > Poultry Environmental Control System >

1000mm 304 SS Roof Air Ventilator , Wind Driven Roof Extractor Fan

Henan Silver Star Poultry Equipment Co.,LTD
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now
    Buy cheap 1000mm 304 SS Roof Air Ventilator , Wind Driven Roof Extractor Fan from wholesalers
     
    Buy cheap 1000mm 304 SS Roof Air Ventilator , Wind Driven Roof Extractor Fan from wholesalers
    • Buy cheap 1000mm 304 SS Roof Air Ventilator , Wind Driven Roof Extractor Fan from wholesalers
    • Buy cheap 1000mm 304 SS Roof Air Ventilator , Wind Driven Roof Extractor Fan from wholesalers

    1000mm 304 SS Roof Air Ventilator , Wind Driven Roof Extractor Fan

    Ask Lasest Price
    Brand Name : Silver Star
    Model Number : YXRF-800
    Certification : ISO9001, SONCAP
    Price : 10-40USD/ Set
    Payment Terms : T/T, Western Union, D/A, D/P, L/C
    Supply Ability : 200000sets/ month
    Delivery Time : 7-10 working days after advanced payment
    • Product Details
    • Company Profile

    1000mm 304 SS Roof Air Ventilator , Wind Driven Roof Extractor Fan

    304 Stainless Steel Non-Power Wind Driven Roof Ventilator
    Natural Air Exhaust Fans


    Non-Power Wind Driven Roof Ventilator Natural Air Exhaust Fans Description

    Non-power wind driven roof ventilator natural air exhaust fans use 304 stainless steel materail with a long life service, with features of zero-cost operating costs, considerable energy efficiency, economical installation costs, and low maintenance costs, which are widely used in poultry chicken farms. Roof ventilator working principle: Turbine ventilators use natural wind and air thermal convection caused by the difference between indoor and outdoor temperature to push the turbine to rotate so as to use centrifugal force and negative pressure to expel the stale indoor hot air.


    Roof Ventilator Natural Air Exhaust Roof Fans Specification

    ModelDiameter(mm)

    Fans Balde Quantity

    (pcs)

    Height(mm)

    Inlet Air

    Speed(m/s)

    Material
    YXRF-400400263903.4304Stainless steel
    YXRF-500500324803.4304Stainless steel
    YXRF-600600326003.4

    304Stainless steel


    YXRF-800800426603.4304Stainless steel
    YXRF-900900487003.4304Stainless stee



    Roof Ventilator Natural Air Exhaust Fans Characteristics:

    1. High-quality structure:
    Rigid spherical structure, permanent lubrication of the upper and lower ball bearings, to ensure a long life and maintenance-free, no need to replace parts, Cases, the American PEER, UBC, Japan NSK high-precision bearing system is fully enclosed and absolutely excellent quality assurance.
    2. Operation of precision equipment:
    UBC high-precision bearing system is fully enclosed, high heat-resistant synthetic grease lubricant, suitable for permanent self-lubricating, non-lubricating best bearings. Be careful, even if there is a breeze of less than 2 kilometers, it is self-supporting.
    3. Green ventilation:
    Adopt the principle of natural wind drive, do not use motor power, avoid the cost of non-electric operation, and do not stop the self-turbine ventilator. Rotating, silent and no noise during operation.
    4. Wide applicability:
    Light steel special-shaped slab roofs of various industrial plants with unique angles in diameter can be installed with concrete roofs. And does not need support, easy to install.


    Maintenance Precautions


    1. Under normal conditions, if the unpowered fan runs continuously for about one month, it is necessary to inject calcium-sodium-based grease or molybdenum disulfide grease into the bearing with a butter station. The fan runs continuously for 3-6 months, and the grease should be replaced once to fill 2/3 of the bearing space.

    2. Regular maintenance of unpowered fans to eliminate dust and dirt inside the fans.

    3. During the startup, shutdown or operation of the unpowered fan, if abnormal conditions are found, including temperature, vibration, noise, etc., they should be overhauled immediately.

    4. Use the adjusting device to keep the triangle tape evenly tensioned and not too loose or too tight. The length of several triangle tapes should be the same as possible.

    5. For unused standby machines or fans that have been out of service for a long time, the rotor should be rotated by 120°-180° regularly to prevent the main shaft from bending. Add a valve to the inlet or outlet of the roof unpowered fan, close it when starting, and open the valve after operation until it reaches the specified working condition, and the inner ring and the shaft fit tightly.

    6. In order to ensure personal safety, the maintenance of the roof unpowered fan must be carried out during shutdown


    Quality 1000mm 304 SS Roof Air Ventilator , Wind Driven Roof Extractor Fan for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Henan Silver Star Poultry Equipment Co.,LTD
    *Subject:
    *Message:
    Characters Remaining: (0/3000)